TS1 Self Refilling Tensiometer

If your task is soil water monitoring you know the problem: water vaporizes and is lost. If soil gets dryer than about 85 kPa, no tensiometer is able to take measurements. Still, as only little water movements occur in extreme dry soil, losing readings is tolerable. Then, when the soil gets wet again, the Tensiometer could actually restart measurements - but first it needs to be refilled again.
Now, the TS1 solves this problem: In case the cup needs to be refilled and soil water is available the internal pump will draw up water out of the soil, refill the cup and remove all air through an exhaust outlet - fully automatically. Even if only a bubble is detected the cup is deaerated automatically. Contrariwise, if the temperature probe indicates emerging frost, the TS1 empties itself to prevent damages caused by freezing.



Typical Applications

  • Ecological impact studies
  • Agricultural studies
  • Model calibration
  • Long time monitoring studies
  • Water balance and transport studies

Advantages

  • Field measurements of pF/wc
  • Automatic self-refilling and deaerating
  • Continuous fill level controlling
  • Optional pore water sampling
  • Automatic emptying before frost
  • Integrated soil temperature probe
  • Integrated data logging function
  • Low maintenance
  • tensioLINK RS-485 interface
  • SDI12 interface

Limitations

  • Not for permanent dry soils

Technical Information

Tensiometer
- Measuring range +100 kPa ... -85 kPa
- Accuracy±0.5 kPa
Temperature
- Measuring range-30 °C ... +70 °C
- Accuracy±0.2 K
Output signal
- Analogselectable ranges: 2 x 0 ... 1 V / 2 V / 5 V
- Digital RS 485 tensioLINK, SDI12
Supply6 ... 18 VDC / typ. 3 mA
HousingØ 40 mm, GFK/PMMA
Cable 1.5 m; 8 pin plug M12

TS1 Self Refilling Tensiometer
TS1 Self Refilling Tensiometer


Processor

As standard two analogue outputs for pressure and temperature are available. For extended measuring tasks like large number of Tensiometers or multi level probes the TS1 can be bus linked.
The configuration of pumping intervals, pumping volume, installation angle etc. is done by PC connection or with an INFIELD7b.
If no correct readings are available an error message is registered. This ensures the data integrity.



Configurations

Art. No. Description

TS1-...

TS1 Tensiometer



Order information

Cable length from sensor body
1,5 m with 20 ... 120 cm total length
2,5 m with 121 ... 211 cm total length


Indicate required total length on an order, e. g. 40 cm = TS1-40

Contact

Georg von Unold
Phone: +49 89 12 66 52- 15
Fax: +49 89 12 66 52 - 20
E-Mail: gvu@ums-muc.de

contact page UMS
Contact Distributors



UMS
measure to know