The T5 Tensiometer is specially made for punctual measurements, for example in soil columns, small lysimeters or pots.
With an active surface of only 0,5 cm2 and a diameter of 5 mm the ceramic tip has all advantages of small dimensions: little soil disturbance, punctual pick-up and fast response.
The special version T5x can achieve a measuring range of 200 kPa.
The T5 can be installed in any position and orientation. Bubbles are easily detectable through the transparent shaft. Output signals are balanced.
| Measuring range | +100 kPa ... -85 kPa |
| Output signal | -100 ... +85 mV |
| Accuracy | ±0.5 kPa |
| Supply | typ. 10.6 VDC / 1.3 mA |
| Shaft | Ø 5 mm |
| Shaft length | 2 ... 20 cm |
| Corpus | Ø 20 mm, length 3.5 cm |
| Cable | 1,5 m; 4-pin plug M12 |

The T5x is the first pressure transducer Tensiometer that can reach an expanded measuring range of up to 200 kPa when it is specially filled (see fig. and ordering information).
Response and filling though are reduced compared to a standard T5.
Indicate required shaft length on an order, e. g. 7 cm = T5-7