Granular matrix sensor with linear output signal.
The SIS is a combination of the well-known Watermark(R) granular matrix soil moisture sensor type 200SS and a special amplifier which offers a fully linearised and temperature compensated DC-voltage output signal.
The amplifier uses a new, patent pending technique for the accurate measurement of the sensor element.
The linear voltage signal reduces the efforts for the electronic measuring equipment and cable connections.
The temperature compensation directly picks up the soil temperature. Thus, the otherwise problematic temperature difference between logger and sensor is avoided.
| Measuring range | -5kPa...-200 kPa |
| Resolution | ±0.2 kPa (5...70 kPa) |
| Temperature* | ±0.1degC (-10...30degC) |
| Alarm signal* | 0 V; +5 V, 2 thresholds with hysteresis, Impedance: 10 kOhm |
| Supply | 6 ... 20 VDC, typ. 2,5 mA |
| Interface* | RS 485 / tensioLINK |
| Matrix Sensor | Watermark, 200SS |
| Size | Ø 25 mm x 116 mm |
The Version SISC4 provide only a linear voltage output 0...2 V for the soil moisture tension.
An extended version (SISC8) features a programmable digital alarm signal for irrigation issues and a serial interface RS 485 / tensioLINK for bus linking and temperature read-out.
- digital alarm signal (e.g. for irrigation issues)
- a serial interface RS 485 / tensioLINK
- temperature read-out with a serial interface
| Art. No. | Description |
SISC4 |
Standard version - Cable length 1.5 m with 4-pin plug M12/IP67, no shaft |
SISC4-... |
Standard version - 4-pin plug M12/IP67, total length selectable between 20 ... 211 cm |
SISC8 |
Extended version - cable length 1,5 m with 8-pin plug M12/IP6, no shaft |
SISC8-... |
Extended version - 8-pin plug M12/IP6, total length selectable between 20 ... 211 cm |
Cable length from sensor body
1,5 m with 20 ... 120 cm total length
2,5 m with 121 ... 211 cm total length
Indicate required total length on an order, e. g. 40 cm = SISC8-40